{"created":"2023-06-19T11:40:47.582741+00:00","id":1023,"links":{},"metadata":{"_buckets":{"deposit":"8a8add49-6615-4eca-b2b5-6e6f9e52a4b2"},"_deposit":{"created_by":14,"id":"1023","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"1023"},"status":"published"},"_oai":{"id":"oai:setsunan.repo.nii.ac.jp:00001023","sets":["120:133:159:160"]},"author_link":["1796","1800","1799","1798","1797","1747"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"54","bibliographicPageStart":"43","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"摂南大学 融合科学研究所論文集"},{"bibliographic_title":"Bulletin of the Transdisciplinary Science Research Institute, Setsunan University","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Triangle odor bag method adopts a self-suction method as a general method of sniffing. However, there is concern about the decrease in suction concentration from the odor bag because of the dilution with the air existing in the mask or the air entering through gaps between the mask and the face. We conducted CFD analysis in order to easily predict airflow properties. Moreover, the measurement of air suction volume assuming the threshold measurement was also conducted in order to verify of the boundary condition in CFD analysis and to grasp the effect on measured thresholds. Consequently, it was revealed that the decrease of odor concentration suctioned from the odor bag was dependent on both the volume of breath, and widths of clearance between the mask and the face. However, there was a small effect on measured thresholds.","subitem_description_type":"Abstract"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2432-5031","subitem_source_identifier_type":"ISSN"}]},"item_10002_text_24":{"attribute_name":"記事種別","attribute_value_mlt":[{"subitem_text_value":"研究論文"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"竹村, 明久"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"堀江, 昌朗"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤本, 侑佑"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAKEMURA, Akihisa","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HORIE, Masaaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"FUJIMOTO, Yusuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-01-30"}],"displaytype":"detail","filename":"2017_003_01_007ts_takemura.pdf","filesize":[{"value":"2.8 MB"}],"format":"application/pdf","license_note":"Copyright (c) 2018 by Setsunan University\n","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"嗅覚を用いた臭気濃度測定法の改善に関する研究 その1 CFD解析と実験に基づく自己吸引手法の検証","url":"https://setsunan.repo.nii.ac.jp/record/1023/files/2017_003_01_007ts_takemura.pdf"},"version_id":"2158af55-12b4-40f8-b26d-c231e0a8b08c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"三点比較式臭袋法","subitem_subject_scheme":"Other"},{"subitem_subject":"臭気濃度","subitem_subject_scheme":"Other"},{"subitem_subject":"嗅覚閾値","subitem_subject_scheme":"Other"},{"subitem_subject":"数値流体力学","subitem_subject_scheme":"Other"},{"subitem_subject":"triangle odor bag method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"odor concentration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"olfactory threshold","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"computational fluid dynamics","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"嗅覚を用いた臭気濃度測定法の改善に関する研究 その1 CFD解析と実験に基づく自己吸引手法の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"嗅覚を用いた臭気濃度測定法の改善に関する研究 その1 CFD解析と実験に基づく自己吸引手法の検証"},{"subitem_title":"Improvement of Measurement Method of Odor Concentration by Olfactory Part 1 Verification of Self-suction Method by CFD Analysis and Experiment","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"14","path":["160"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-01-30"},"publish_date":"2018-01-30","publish_status":"0","recid":"1023","relation_version_is_last":true,"title":["嗅覚を用いた臭気濃度測定法の改善に関する研究 その1 CFD解析と実験に基づく自己吸引手法の検証"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-06-19T12:18:55.592342+00:00"}